FREE Delivery on all orders for Limited time

Search

Out of stock

POLYOXAL LB | 50ML Dental Light Body Silicone Impression Material | Automix Double Barrel Syringe

  • Light body addition cure silicone
  • Precision silicone for use with Polyoxal Putty
  • High stability, for use in double
  • impression technique
  • 50ML Double Barrel

Hydrophilic vinyl polysiloxane Impression Material

1,000.00 inc. GST

Compare
Hydrophilic Vinyl Siloxane Impression Material
Polyoxal is available in 3 consistencies and is easy to apply for precision dental impression taking.
POLYOXAL LB: LOW VISCOSITY
Double impression technique correcting
material. Syringe material meets requirements of
DIN 13913 C1, ISO 4823 Type 3 Cat A.
INTRODUCTION: Polyoxal is available in 3consistencies and is easy to apply for precision dental impression taking. POLYOXAL HB PUTTY: Primary impression material for doubleimpression technique. Meets the requirements of DIN 13913 A1, ISO 4823 Type I, Cat. A POLYOXAL MB: MEDIUM VISCOSITY Syringe material, double mixing technique, impression taking of edentulous jaws, and denture re-lining impression taking. Meets the requirements of DIN 13913 C1, ISO 4823 Type3 Cat. A. POLYOXAL LB: LOW VISCOSITY Double impression technique correcting material. Syringe material meets requirements of DIN 13913 C1, ISO 4823 Type 3 Cats A. MIXING RATIO: Equal parts 1:1 (volume or weight) of base and catalyst paste are recommended which although different in colour, have the same consistency, so that an easily controlled homogeneous mix is obtained. Polyoxal HB: Using the separate measuring spoons, dose 1 level scoopful of each and knead for 1 minute to obtain a homogeneous colour. APPLICATION: Polyoxal LB: Low Viscosity Dosage 1:1 2min.30sec-------------- 3.00min------- -----4:00. Holding Time                Remove

                 in mouth                  from Mouth

Use typically at 23°C. Relative humidity: 50%.Higher temperature shortens these times and lower temperatures lengthen these times. IMPORTANT: Latex based rubber gloves should not be used when mixing Polyoxal HB. Tubs and syringes should be closed immediately after use, with the correct closures. Do not interchange the caps of the tubs. The impression can be poured 1 hour after removal. STORAGE: Maximum temperature 25°C, relative humidity 50 5%. Do not use after expiry date. CAUTION: Avoid contact with the eyes. In case of contact occurs wash immediately with plenty of water or use eye-washers. Seek medical advice if necessary. Material may stain clothing.   Click here to download MSDS.

Back to Top
Product has been added to your cart